Dealing in a wide Range of Crucible and Lab ware:
  • Alumina Crucible
  • Silica Crucible
  • Graphite Crucible
  • Porcelain Crucible
  • Platinum Crucible
  • Nickle Crucible
  • Titanium Crucible
  • Silicon Carbide Crucible


Alumina TA Pans for TGA, DTA & DSC

REQUEST CALLBACK

Alumina TA Pans for TGA, DTA & DSC
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 100 / PieceGet Latest Price

Product Details:
Minimum Order Quantity10 Piece
MaterialSilicon Graphite
Max Temperature1500-2000 degree Celsius
Usage/ApplicationLaboratory
Volume1ML
ColorWHITE
BrandMXRADY
Country of OriginMade in India

TA pans for TGA, DTA and DSC.Max working temp: 1700 Degree Celsius.We can provide all company Instrument Pans.


Additional Information:

  • Item Code: AC
  • Production Capacity: 50
  • Delivery Time: 1 WEEK
  • Packaging Details: corrugated box+ THEROCOL+ BUBBLE SHEET
Yes! I am Interested

Alumina Crucible 90ul 6.5mm x 4mm

REQUEST CALLBACK

Alumina Crucible 90ul 6.5mm x 4mm
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 100 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
MaterialALUMINA
Max Material AmountALUMINA
Max Temperature0-1000 degree Celsius
Usage/ApplicationTA PAN
Volume10ul
Crucible Height10mm
Crucible Diameter6mm
Colorwhite
BrandMXRADY

Alumina 90ul Crucible, 6.5mm x 4mm TGA / DSC Sample Pan LABORATORY AND ANALYSER APPLICATION
Yes! I am Interested

LARK High Temp Alumina Crucible 50mL (1750 Degree Celsius)

REQUEST CALLBACK

LARK High Temp Alumina Crucible 50mL (1750 Degree Celsius)
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 900 / PieceGet Latest Price

Product Details:
Minimum Order Quantity5 Piece
MaterialClay Graphite
Max Temperature1500-2000 degree Celsius
Usage/ApplicationLaboratory
Volume50ml
BrandLARK
Model Name/Number50ml

Alumina products are fragile. Please handle them carefully and avoid collision during unpacking, transportation, handling and cleaning. Check whether any micro-cracks exist before using alumina products. Products with micro-cracks should not be used. Alumina products should be completely dry before usage. If they get wet, let the crucible or tube dry naturally before using them. If dry crucibles by placing in a dryer or oven, make sure that the dry process goes slowly. Do not load too many materials in alumina crucibles, which can increase the possibility of uneven heating. Alumina crucibles are sensitive to thermal shock. Try to warm up the furnace chamber slowly. A heating rate of 150°C/hour is recommended for the first 1-1.5 hours so that the crucibles can be evenly heated to reduce the impact of thermal shock. It usually takes about 3 hours to increase to high temperature. Lower the temperature as gradually as possible. The cooling down rate is often half of the heating rate. If possible, arrange for consecutive heating of furnace to maintain a hot crucible. If taking the crucibles out of furnace into room temperature to pour the melted material, try to control the process as short as possible. Avoid contact of heated alumina products with a cold surface. Use insulation materials as support of alumina crucibles.100% Brand New And High Quality. Durable, With Good Stability.


Additional Information:

  • Item Code: AC-50ml
  • Production Capacity: 50ml
  • Delivery Time: 4 to 5 Days
Yes! I am Interested

LARK High Temp Alumina Crucible 200mL (1750 Degree Celsius)

REQUEST CALLBACK

LARK High Temp Alumina Crucible 200mL (1750 Degree Celsius)
  • LARK High Temp Alumina Crucible 200mL (1750 Degree Celsius)
  • LARK High Temp Alumina Crucible 200mL (1750 Degree Celsius)
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1,500 / PieceGet Latest Price

Product Details:
Minimum Order Quantity5 Piece
MaterialClay Graphite
Max Temperature1500-2000 degree Celsius
Usage/ApplicationLaboratory
Volume200
ColorWhite
BrandLARK
Capacity200ml
Bottom Diameter44

Alumina products are fragile. Please handle them carefully and avoid collision during unpacking, transportation, handling and cleaning. Check whether any micro-cracks exist before using alumina products. Products with micro-cracks should not be used. Alumina products should be completely dry before usage. If they get wet, let the crucible or tube dry naturally before using them. If dry crucibles by placing in a dryer or oven, make sure that the dry process goes slowly. Do not load too many materials in alumina crucibles, which can increase the possibility of uneven heating. Alumina crucibles are sensitive to thermal shock. Try to warm up the furnace chamber slowly. A heating rate of 150°C/hour is recommended for the first 1-1.5 hours so that the crucibles can be evenly heated to reduce the impact of thermal shock. It usually takes about 3 hours to increase to high temperature. Lower the temperature as gradually as possible. The cooling down rate is often half of the heating rate. If possible, arrange for consecutive heating of furnace to maintain a hot crucible. If taking the crucibles out of furnace into room temperature to pour the melted material, try to control the process as short as possible. Avoid contact of heated alumina products with a cold surface. Use insulation materials as support of alumina crucibles.100% Brand New And High Quality. Durable, With Good Stability.


Additional Information:

  • Item Code: AC-200ml
  • Production Capacity: 200ml
  • Delivery Time: 4 to 5 days
Yes! I am Interested

LARK High Temp Alumina Crucible 250mL (1750 Degree Celsius)

REQUEST CALLBACK

LARK High Temp Alumina Crucible 250mL (1750 Degree Celsius)
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1,900 / PieceGet Latest Price

Product Details:
Minimum Order Quantity5 Piece
MaterialClay Graphite
Max Temperature1500-2000 degree Celsius
Usage/ApplicationLaboratory
Volume250ml
Crucible Height76
ColorWhite
BrandLARK
Capacity250ml
Bottom Diameter44
Model Name/Number200ml

Alumina products are fragile. Please handle them carefully and avoid collision during unpacking, transportation, handling and cleaning. Check whether any micro-cracks exist before using alumina products. Products with micro-cracks should not be used. Alumina products should be completely dry before usage. If they get wet, let the crucible or tube dry naturally before using them. If dry crucibles by placing in a dryer or oven, make sure that the dry process goes slowly. Do not load too many materials in alumina crucibles, which can increase the possibility of uneven heating. Alumina crucibles are sensitive to thermal shock. Try to warm up the furnace chamber slowly. A heating rate of 150°C/hour is recommended for the first 1-1.5 hours so that the crucibles can be evenly heated to reduce the impact of thermal shock. It usually takes about 3 hours to increase to high temperature. Lower the temperature as gradually as possible. The cooling down rate is often half of the heating rate. If possible, arrange for consecutive heating of furnace to maintain a hot crucible. If taking the crucibles out of furnace into room temperature to pour the melted material, try to control the process as short as possible. Avoid contact of heated alumina products with a cold surface. Use insulation materials as support of alumina crucibles.100% Brand New And High Quality. Durable, With Good Stability.


Additional Information:

  • Item Code: AC-250ml
  • Production Capacity: 250ml
  • Delivery Time: 4 to 5 days
Yes! I am Interested

LARK High Temp Alumina Crucible 500mL (1750 Degree Celsius)

REQUEST CALLBACK

LARK High Temp Alumina Crucible 500mL (1750 Degree Celsius)
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 3,600 / PieceGet Latest Price

Product Details:
Minimum Order Quantity2 Piece
MaterialClay Graphite
Max Temperature1500-2000 degree Celsius
Usage/ApplicationLaboratory
Volume500
Crucible Height112
ColorWhite
BrandLARK
Capacity500ml
Bottom Diameter98
Model Name/Number500ml

Alumina products are fragile. Please handle them carefully and avoid collision during unpacking, transportation, handling and cleaning. Check whether any micro-cracks exist before using alumina products. Products with micro-cracks should not be used. Alumina products should be completely dry before usage. If they get wet, let the crucible or tube dry naturally before using them. If dry crucibles by placing in a dryer or oven, make sure that the dry process goes slowly. Do not load too many materials in alumina crucibles, which can increase the possibility of uneven heating. Alumina crucibles are sensitive to thermal shock. Try to warm up the furnace chamber slowly. A heating rate of 150°C/hour is recommended for the first 1-1.5 hours so that the crucibles can be evenly heated to reduce the impact of thermal shock. It usually takes about 3 hours to increase to high temperature. Lower the temperature as gradually as possible. The cooling down rate is often half of the heating rate. If possible, arrange for consecutive heating of furnace to maintain a hot crucible. If taking the crucibles out of furnace into room temperature to pour the melted material, try to control the process as short as possible. Avoid contact of heated alumina products with a cold surface. Use insulation materials as support of alumina crucibles.100% Brand New And High Quality. Durable, With Good Stability.


Additional Information:

  • Item Code: AC-500ml
  • Production Capacity: 500
  • Delivery Time: 4 to 5 days
Yes! I am Interested

LARK High Temp Alumina Crucible 15mL (1750 Degree Celsius)

REQUEST CALLBACK

LARK High Temp Alumina Crucible 15mL (1750 Degree Celsius)
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 400 / PieceGet Latest Price

Product Details:
Minimum Order Quantity10 Piece
MaterialClay Graphite
Max Temperature1500-2000 degree Celsius
Usage/Applicationlaboratory
Volume15
Crucible Height33
ColorWhite
BrandLARK
Capacity15
Bottom Diameter25

Alumina products are fragile. Please handle them carefully and avoid collision during unpacking, transportation, handling and cleaning. Check whether any micro-cracks exist before using alumina products. Products with micro-cracks should not be used. Alumina products should be completely dry before usage. If they get wet, let the crucible or tube dry naturally before using them. If dry crucibles by placing in a dryer or oven, make sure that the dry process goes slowly. Do not load too many materials in alumina crucibles, which can increase the possibility of uneven heating. Alumina crucibles are sensitive to thermal shock. Try to warm up the furnace chamber slowly. A heating rate of 150°C/hour is recommended for the first 1-1.5 hours so that the crucibles can be evenly heated to reduce the impact of thermal shock. It usually takes about 3 hours to increase to high temperature. Lower the temperature as gradually as possible. The cooling down rate is often half of the heating rate. If possible, arrange for consecutive heating of furnace to maintain a hot crucible. If taking the crucibles out of furnace into room temperature to pour the melted material, try to control the process as short as possible. Avoid contact of heated alumina products with a cold surface. Use insulation materials as support of alumina crucibles.100% Brand New And High Quality. Durable, With Good Stability.


Additional Information:

  • Item Code: AC-15ml
  • Production Capacity: 15ml
  • Delivery Time: 4 to 5 days
Yes! I am Interested

LARK High Temp Alumina Crucible 25mL (1750 Degree Celsius)

REQUEST CALLBACK

LARK High Temp Alumina Crucible 25mL (1750 Degree Celsius)
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 300 / PieceGet Latest Price

Product Details:
Minimum Order Quantity10 Piece
MaterialClay Graphite
Usage/Applicationlaboratory
Volume25
Max Temperature1500-2000 degree Celsius
Crucible Height36
ColorWhite
BrandLARK
Capacity25
Bottom Diameter25
Model Name/Number25ml

Alumina products are fragile. Please handle them carefully and avoid collision during unpacking, transportation, handling and cleaning. Check whether any micro-cracks exist before using alumina products. Products with micro-cracks should not be used. Alumina products should be completely dry before usage. If they get wet, let the crucible or tube dry naturally before using them. If dry crucibles by placing in a dryer or oven, make sure that the dry process goes slowly. Do not load too many materials in alumina crucibles, which can increase the possibility of uneven heating. Alumina crucibles are sensitive to thermal shock. Try to warm up the furnace chamber slowly. A heating rate of 150°C/hour is recommended for the first 1-1.5 hours so that the crucibles can be evenly heated to reduce the impact of thermal shock. It usually takes about 3 hours to increase to high temperature. Lower the temperature as gradually as possible. The cooling down rate is often half of the heating rate. If possible, arrange for consecutive heating of furnace to maintain a hot crucible. If taking the crucibles out of furnace into room temperature to pour the melted material, try to control the process as short as possible. Avoid contact of heated alumina products with a cold surface. Use insulation materials as support of alumina crucibles.100% Brand New And High Quality. Durable, With Good Stability.


Additional Information:

  • Item Code: AC-25ml
  • Production Capacity: 25ml
  • Delivery Time: 4 to 5 days
Yes! I am Interested

Desiccator vacuum

REQUEST CALLBACK

Desiccator vacuum
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1,200 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Country of OriginMade in India
BRANDMXRADY
AutoclavableYES
TYPEGLASS
SIZEANY
USAGELABORATORY
COLORTRANSPARENT

Desiccators are sealable enclosures containing desiccants used for preserving moisture-sensitive items such as cobalt chloride paper for another use. A common use for desiccators is to protect chemicals which are hygroscopic or which react with water from humidity.The contents of desiccators are exposed to atmospheric moisture whenever the desiccators are opened. It also requires some time to achieve a low humidity. Hence they are not appropriate for storing chemicals which react quickly or violently with atmospheric moisture such as the alkali metals; a glovebox or Schlenk-type apparatus may be more suitable for these purposes.Desiccators are sometimes used to remove traces of water from an almost-dry sample. Where a desiccator alone is unsatisfactory, the sample may be dried at elevated temperature using Abderhalden's drying pistol.


Additional Information:

  • Production Capacity: 50
  • Delivery Time: 2DAYS
  • Packaging Details: STANDER PACKING
Yes! I am Interested

Microwave Leakage Detector

REQUEST CALLBACK

Microwave Leakage Detector
  • Microwave Leakage Detector
  • Microwave Leakage Detector
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 3,500 / PieceGet Latest Price

Product Details:
BrandHSETIN
MaterialABS
ColorYellow
Weight112gm
MODEL NO.HT-M2
Range0~9.99mW/cm
Calibrated2450MHz
Accuracy+-1dB


HSETIN Microwave Leakage Detector allows the user to measure radiation emission levels from microwave ovens. Readings in mW/cm2 are given instantly from 0 to 9.9mW/cm2 and there is an audible tone and red warning LED when leakage exceeds permitted levels.
  1. LCD digital readout
  2. Low leakage volume display for warming
  3. Human factor engineering design is suitable for the operation of the both hand
  4. 1 year life battery
  5. Never needs recalibration
  6. High sensitivity to the microwave
  7. Excellent reliability and high precision
  8. Calibrated at:2450MHz
  9. Range:0-99.9mW/cm2
  10. Warning value:5.0mW/cm2
  11. Accuracy:+1dB
  12. Power source:9V battery
  13. Warranty: 1 Year


Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 1 Day
Yes! I am Interested

Deuterium Lamp

REQUEST CALLBACK

Deuterium Lamp
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 24,500 / PieceGet Latest Price

Product Details:
Country of OriginMade in India
InstrumentShimadzu
ModelAA700
ItemDeuterium Lamp
Applicationspare of lamps
StockReady

Deuterium Lamp
The discharge voltage of standard deuterium lamp is 60-70V, radiation energy of which is 1.2 times of that of imported ones. The service time of our deuterium lamp is 1000 hours while the lamp of 2000-hour service time is under development. The noise P-P value is less than 3×10-4; brightness drift is less than 0.16%; the filaments can be customized according to customer’s design.
For more info kindly contact us


Additional Information:

  • Item Code: D2S
  • Production Capacity: 100
  • Delivery Time: 1
Yes! I am Interested

Soda Glass Dessicator, High Grade

REQUEST CALLBACK

Soda Glass Dessicator, High Grade
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 750 / PieceGet Latest Price

Product Details:
Size:100mm, 120mm, 150mm, 180mm, 210mm, 240mm, 350mm, 400mm
Material:Soda Lime Glass (Clear)
Brand:HBG
Cover:Yes
Plate:Yes
Application:Lab Analysis

Glass Vacuum Desiccator is sealable enclosures containing desiccants used for preserving moisture-sensitive items such as cobalt chloride paper for other use. A common use for desiccators is to protect chemicals that are hygroscopic or which react with water from humidity.



Additional Information:

  • Production Capacity: 1000
Yes! I am Interested

Magnetic Stiirer Beads Oval Shaped

REQUEST CALLBACK

Magnetic Stiirer Beads Oval Shaped
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 50 / PieceGet Latest Price

Product Details:
MaterialPTFE
Model NameOVAL
Model NumberNA

Available in: 
6*10mm Oval
7*15mm Oval
8*20mm Oval
9*25mm Oval
Yes! I am Interested

Alumina Crucible Temp withstand 800 Degrees

REQUEST CALLBACK

Alumina Crucible Temp withstand 800 Degrees
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 800 / PieceGet Latest Price

Product Details:
Minimum Order Quantity5 Piece
Max Temperature0-1000 degree Celsius

Having a temperature resistance of 800C, our Crucible Range has a unique quality which make us the leading dealer of Alumina Crucibles. This can be taken as a replacement for High Price Porcelain Crucibles.

Features:
  • Temp.: 800°C
  • Available in 15 ml, 25 ml, 30 ml, 50 ml, 100 ml, 150 ml, 200ml, 250ml, 500ml, 1000ml etc.

Specification:


It. CodeVolume
(ml)
Upper OD
(mm)
Bottom OD
(mm)
Height
(mm)
AC-1515352533
AC-2525402536
AC-3030402337
AC-4545
AC-5050533045
AC-8080
AC-10010063.543.574.5
AC-15015066.53274
AC-200200694475
AC-250250724476
AC-350350814986
AC-50050010198112
AC-10001000 ml

Application: Schools, Laboratories, Research Institutes & other General Laboratories which do not need Precise applications.
Yes! I am Interested

Porous Crucibles

REQUEST CALLBACK

Porous Crucibles
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 4,000 / PieceGet Latest Price

Product Details:
Minimum Order Quantity5 Piece
MaterialSilicon Graphite
ColorWhite
BrandMxRady

Porcelain, Porous bottom crucible, with porous disc permanently formed into walls. Stable porosity and rate of flow. Available with very fine (1.2 micron), fine (5 micron) and medium (15 micron) pore dia.


Additional Information:

  • Delivery Time: 3 Days
Yes! I am Interested

Vacuum Laboratory Desiccator

REQUEST CALLBACK

Vacuum Laboratory Desiccator
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1,200 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
Size:120mm, 200mm, 240mm etc

 Vacuum Desiccator is sealable enclosures containing desiccants used for preserving moisture-sensitive items such as cobalt chloride paper for other use. A common use for desiccators is to protect chemicals that are hygroscopic or which react with water from humidity.
Yes! I am Interested

Graphite Crucible for Furnace Application

REQUEST CALLBACK

Graphite Crucible for Furnace Application
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 7,500 / PieceGet Latest Price

Product Details:
MaterialSilicon Graphite
Max Material Amountna
Max Temperature1500-2000 degree Celsius
Usage/ApplicationVaccum Coating
Volume100
Crucible Height135mm
Crucible Diameter135mm
ColorGrey
BrandALMATH (UK)

Graphite crucible can withstand the high temperature, and has good resistance to chemical erosions and thermal shock. Especially graphite crucible is ideal for the melting of aluminum, copper and other metals.
Yes! I am Interested

Quartz Cumbustible Boats (Material of USA)

REQUEST CALLBACK

Quartz Cumbustible Boats (Material of USA)
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 700 / PieceGet Latest Price

Product Details:
Minimum Order Quantity10 Piece
BrandLARK
Usage/ApplicationChemical Laboratory
MaterialQUARTZ
FinishingNA
Packaging TypeNA
ShapeBoat
Thickness2mm

Our firm is considered as one of the leading firms that manufacture and export a quality range of Quartz Boat all around the world. Made up of high-quality raw material these are quality tested at each step of manufacturing and are completely authenticated. Quartz Boat is extremely robust and are highly durable in nature.

Specification:
  • Operating temperature: 1150 degree Celsius
  • UV transparent - YES
Yes! I am Interested

Quartz Low Form Crucible with Lid

REQUEST CALLBACK

Quartz Low Form Crucible with Lid
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 850 / PieceGet Latest Price

Product Details:
Minimum Order Quantity1 Piece
MaterialQuartz
Capacity25ml
Usage/ApplicationChemical Laboratory
ColorTransparent
ShapeLow Form
Packaging Type1 pc

Quartz crucibles supplies high temperature resistant containers that are chemically inert and resistant to thermal shock. Quartz Crucibles are used by semiconductor and solar industries for growing single crystal from silicon melt at about 1400°C. Opaque quartz crucibles can also be used in other industrial applications such as glass melting, chemical processing and powder calcinations because of their high purity and excellent chemical resistance.

ITEM NUMBER

CAPACITY (cc)

TOP DIAMETER (mm)

BASE DIAMETER (mm)

HEIGHT (mm)

CL10

10

28

14

30

CL20

20

36

17

40

CL30

30

43

22

38

CL50

50

50

22

48

CL100

100

62

35

66


Additional sizes are available upon request.

Yes! I am Interested

Milwaukee ORP Meter MW-500

REQUEST CALLBACK

Milwaukee ORP Meter MW-500
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 11,200 / PieceGet Latest Price

Product Details:
Model Name/NumberMilwaukee MW-500
Usage/ApplicationLaboratory
AccuracyThe PRO ORP meter is accurate to +-5 mV
Powerlow power demand for a 300 hour extended battery life
MountingNA
Battery Life300 hour

The Milwaukee MW500 PRO ORP meter is one of Milwaukee's most popular meters with its reliable, fast and simple operation as well as its accuracy.

The Milwaukee PRO ORP Meter is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are aquariums, swimming pools and spas, and other water quality monitoring uses.

The PRO ORP meter can also be used to measure sulfur dioxide in wine using the manual Ripper titration method.


Yes! I am Interested

Imported High Grade Gasification Graphite Crucible For Vacuum Coating

REQUEST CALLBACK

Imported High Grade Gasification Graphite Crucible For Vacuum Coating
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 8,500 / PieceGet Latest Price

Product Details:
MaterialSilicon Graphite
Max Material AmountN.A
Max Temperature3000 degree Celsius
Usage/ApplicationGasification graphite crucible for vacuum coating aluminum
VolumeN.A

The main purpose of the graphite crucible is to heat the experimental material that needs to be heated. Generally, the graphite crucible is used to heat the solid material in the experiment. The graphite crucible has a variety of models. The crucible can be selected according to the number and type of materials to be heated and the degree of thermal expansion. model. In general, when using graphite crucibles, we must pay attention not to fill the crucible with heated materials, which is very dangerous, not only easily cause experimental accidents, but also have a great impact on the life of the graphite crucible. 

OD

ID

HEIGHT

THICKNESS

135mm

115mm

120mm

10mm



Additional Information:

  • Production Capacity: 1000
Yes! I am Interested

Alumina Boats & Labware

REQUEST CALLBACK

Alumina Boats & Labware
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 240 / PcsGet Latest Price

Product Details:
Minimum Order Quantity10 Pcs
ApplicationChemical Laboratory
BrandLARK

We are dealing in High Quality Alumina Boats which can take temp upto 1750 Degree Celsius. Standard Volume Include 3ml, 7ml, 15ml, 30ml, 40ml etc. Apart from these, other sizes also available. Price change as per the parameters & qty. Assurance of Best Quality with Lowest Price!!


Additional Information:

  • Item Code: AB-25
  • Production Capacity: 1000
  • Delivery Time: 2-3 Weeks
  • Packaging Details: Alumina Boats
Yes! I am Interested

DSC Pans And Lids

REQUEST CALLBACK

DSC Pans And Lids
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 220 / PieceGet Latest Price

Product Details:
MaterialAluminium
ColorSilver

DSC measurement requires that samples are enclosed in a sample pan in order to avoid the direct contact between sample and furnace and/or sensor, because if the samples come into contact with the furnace/sensor problems can occur on the baseline. Memory can be affected and damage to the furnace/sensor can occur (in the worst case the furnace/sensor can be destroyed).
Yes! I am Interested

Platinum Crucible and Lid

REQUEST CALLBACK

Platinum Crucible and Lid
  • Platinum Crucible and Lid
  • Platinum Crucible and Lid
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 3,500 / GramGet Latest Price

Product Details:
MaterialPLATINUM
Max Material AmountPLATINUM
Max Temperature1000-1500 degree Celsius
Usage/ApplicationPLATINUM METLING
Volume25ML
Country of OriginMade in India

Ours is an illustrious organization that is engaged in manufacturing, supplying and exporting high quality Platinum Crucibles. All these products are demanded for melting, analyzing and calcining different materials at high temperatures. The offered platinum crucibles are developed using extra thick base that can easily resist heavy wear. Our range is provided with lid.

Features:
  • Durable
  • High material strength
  • Light Weight
  • Extra thick base

Specifications:

Shape: 'AZ / UA

Available Sizes:-
15 ml
25 ml
30 ml
35 ml
50 ml
100 ml

Yes! I am Interested

Alumina Tray

REQUEST CALLBACK

Alumina Tray
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 550 / PcsGet Latest Price

Product Details:
Minimum Order Quantity10 Pcs
Usage/ApplicationChemical Laboratory
MaterialALUMINA
Packaging Type1 PC
ColorWHITE
BrandMXRADY
Packaging Size1 PC
Number Of LegNA

Alumina Tray available in 5ml, 10ml, 25, 80, 100, 225ml. Apart from this, other sizes also available. Price change as per the parameters and qty.


Additional Information:

  • Item Code: AT-25
  • Production Capacity: 1000
  • Delivery Time: 2-3 Weeks
  • Packaging Details: Customised
Yes! I am Interested

Alumina Dish

REQUEST CALLBACK

Alumina Dish
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 240 / PieceGet Latest Price

Product Details:
Minimum Order Quantity10 Piece
ColorWHITE
Diameter10MM
MaterialALUMINA
BrandMXRADY
Sizes10MM
FeatureALUMINA MELTING
Max Volume10ML

We are dealing in High Quality Alumina Dishes. It take take temperature upto 1750 Degree Celsius. Standard Sizes include 10ml, 20ml, 40ml, 100ml, 250ml etc. Other sizes can be made on order.


Additional Information:

  • Item Code: AD-25
  • Production Capacity: 1000
  • Delivery Time: 2-3 Weeks
Yes! I am Interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Suman Dosad (Sales Head)
Mxrady Lab Solutions Private Limited
KD 6, MIG Flats, Pitam Pura
New Delhi - 110034, Delhi, India
Call Us: 
Call Response Rate: 85%
Share Us :



Home  |   Profile   |  Our Products  |  Site Map  |   Contact Us

© Mxrady Lab Solutions Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Mxrady Lab Solutions Private Limited